Resistance to contortion, breakage and fatigue. There are no existing analytical models which allow for the choice of window according to these parameters, and it is thus necessary to refer to experience with models and sizes similar to the one that is being designed.
In any case, this group of requirements can be specified with the UNE 85-213 norm code, as a function of the pressure figure previously obtained according to table 3.
Table 3
Window class according to pressure figure
Pressure figure, w
Pa
<200 <500 <1000 <1500 >1500
Window of the
UNE 85-214
norm type
* VI V2 V3 **
* wind action is not the determining factor in establishing the required degree of resistance of the window
**a special window, more resistant than V3.
Key: V1, V2 and V3 are window classification codes tested according to UNE norm 85-204, which give the results set out in table 4.
Table 4
Window class according to UNE norm UNE 85-204
Classification code   VI V2 V3
Contortion Pressure with arrows less than
1/300 of the length of the bar
Pa
500 1000 1500
Fatigue Pressure in pressure/suction cycles
conserving characteristics with no
residual contortion. Pa
400 800 1200
Breakage Safety pressure without breakage or
sudden opening. Pa
900 1700 2400
Classification of windows by wind resistance. When the manufacturer makes standardised series, they should supply details of the degree of wind resistance of each model.
In the same way, the manufacturer of series of bars should supply details of the degree of resistance achieved by each group on a finely graded scale.
The table shows the type of window required as a function of the parameters cited above for a number of common situations.
Location of building Height of window from ground level in metres. Location of the window
In patios In protected facade In exposed facade
Area according to map 1
w x y z w x y z w x y z
Centres of large cities 50
30
20
<10
-
-
-
-
VI
-
-
-
VI
VI
-
-
VI
VI
VI
VI
V2
VI
VI
VI
V2
VI
VI
VI
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V2
V3
V2
V2
V2
V3
V3
V3
V3
Urban areas 50
30
20
<10
VI
-
-
-
VI
VI
-
-
VI
VI
VI
-
VI
VI
VI
VI
V2
V2
VI
VI
V2
V2
V2
VI
V2
V2
V2
V2
V3
V2
V2
V2
V3
V2
V2
V2
V3
V3
V2
V2
V3
V3
V2
V2
*
V3
V3
V3
Rural areas 30
20
10
<5
VI
VI
-
-
VI
VI
-
-
VI
VI
VI
-
VI
VI
VI
VI
V2
V2
VI
VI
V2
V2
V2
VI
V2
V2
V2
V2
V3
V2
V2
V2
V3
V2
V2
V2
V3
V3
V2
V2
V3
V3
V3
V2
*
V3
V3
V3
Open land with no obstructions 20
10
5
<3
VI
VI
-
-
VI
VI
VI
-
VI
VI
VI
VI
VI
VI
VI
VI
V2
V2
VI
VI
V2
V2
V2
VI
V2
V2
V2
V2
V3
V2
V2
V2
V3
V2
V2
V2
V3
V3
V2
V2
V3
V3
V3
V2
*
V3
V3
V3
The symbol - indicates that wind action is not the determining factor in establishing the required degree of resistance of the window.
The symbol * means that a special window will be necessary.
When a double window solution is adopted, a class VI window will be sufficient for the interior one while the exterior should be V2 o V3.
 
NOTE:
In the parts of this catalogue dealing with each series, a Usage Limit Graph, is included which can be used for quick calculations of maximum leaf dimensions depending on the bars used and the conditioning factors of location and wind action, established with the above tables. In the same way the Classification V for each series is indicated. Obviously these technical characteristics are only guaranteed for leaf dimensions that fall within the graphs.